Thursday, January 24, 2013

Brother HL 2140 Windows 8 Printer Driver for USB-Network Print server

If you connect your Brother HL 2140 to a USB-Network Print server, and add this printer by using adding network printer method.

You will ask for install a driver, you can download the following driver:

http://download.brother.com/welcome/dlf004108/Y07C_C1-inst-win7-A2-enus.EXE

And run this exe file to unzip (But do not execute the setup.exe, once the unzip is complete)

Then, use broswe to the “install\usa\PCL\Win7_64” (For 64bits Windows 8) or “install\usa\PCL\Win7” (For 32bits Windows 8) for install the driver. Print Friendly and PDF
Share/Bookmark

Monday, January 21, 2013

How to force Directory Synchronization for Office 365

Force a manual Directory Synchronization for your Office 365 tenant

Step 1:

Login to DIRSYNC server - the server which is running the Directory Synchronization Tools

Step 2:

Start a PowerShell session (e.g. Open a command prompt -> enter "powershell")

image

Step 3:

cd "C:\Program Files\Microsoft Online Directory Sync"

image

Step 4:

C:\Program Files\Microsoft Online Directory Sync>.\DirSyncConfigShell.psc1

clip_image002

Step 5:

C:\Program Files\Microsoft Online Directory Sync>Start-OnlineCoexistenceSync

image

Open the "Synchronization Service Manager" - Go to "C:\Program Files\Microsoft Online Directory Sync\SYNCBUS\Synchronization Service\UIShell\miisclient.exe"

To check the action of the DS and also the result:

image Print Friendly and PDF
Share/Bookmark

HP WMS Zero Client Service restart it will be able to reconnect all the T200 client

If some of the HP T200 client connect to HP MS6200 and there are some display incorrect (e.g. some client seen the other client login screen/user session screen).

Instead of reboot the server, restart the “HP WMS Zero Client Service” will be able to solve this issue:

image

Print Friendly and PDF
Share/Bookmark

Sunday, January 20, 2013

Lenovo ThinkPad Edge E130 install 8GB x 2 (Total: 16GB) running Windows 8 64bits

The Lenovo ThinkPad Edge E130 which is using Intel HM77. I try to install TWO 8GB DDR3 1600MHz RAM to this laptop and running well.

image

image

Print Friendly and PDF
Share/Bookmark

Monday, January 14, 2013

How to use the Outlook 2003 forms cache and to troubleshoot forms cache problems

outlook

The solution at the following:

1. On the Tools menu, click Options, and then click the Other tab.

2. Click Advanced Options.

3. In the Advanced Options box, click Custom Forms.

4. In the Custom Forms box, click Manage Forms.

5. In the Forms Manager box, click Clear Cache.

Reference:

http://support.microsoft.com/kb/839804 Print Friendly and PDF
Share/Bookmark

Sunday, January 13, 2013

Solve the problem of running Symantec EV for Microsoft Outlook 2003 on MS MPS 2011

When you open the outlook 2003 on MPS 2011, you will got the following error from EV plug-in:

image

The problem is casued by the Outlvbs.dll is missing.

Solution:

1. To solve the problem of running Symantec EV of Outlook 2003 on MS MPS 2011, we need to copy the missing dll file “Outlvbs.dll” from a machine which is running EV and also not running in terminal server. 

2. Copy the “Outlvbs.dll” from “C:\Program Files (x86)\Microsoft Office\OFFICE11” (A Windows 7 64 bits machine) to the MPS server “C:\Program Files (x86)\Microsoft Office\OFFICE11”

3. And then re-open the outlook on MPS 2011.

The problem will be solved.

Reference:

http://www.symantec.com/connect/forums/ev-and-citrix

http://support.microsoft.com/default.aspx?scid=kb;en-us;302003

Print Friendly and PDF
Share/Bookmark

Asus EEEPC 1008HA cannot display issue after cold boot (upgraded to Windows 7)

This issue is caused by BIOS.

If your BIOS is 0402 or before, you will hit this issue after you upgrade your Windows XP to Windows 7.

The solution is upgrade the BIOS to 1103.

http://support.asus.com/Download.aspx?SLanguage=en&p=20&s=1&m=Eee%20PC%201008HA&os=29&ft=3&f_name=1008HA-ASUS-1103.zip#1008HA-ASUS-1103.zip

Since the BIOS 0402 is very old (There are at least BIOS release 0801 and 1001 which is newer than this BIOS) (The latest one is 1103 which is we are going to upgrade)

You will not able to use the ASUS LiveUpdate and EZ Flash.

If you use the ASUS LiveUpdate, you will just reboot the machine without update the BIOS.

If you use EZ-Flash, you will hang up at “Reading file “1008HA.ROM” ”

image

So, you will need to use the use a USB thumb drive to boot to the DOS and run the BIOS update at Pure DOS environment.

For the Bootable DOS USB thumb drive create and BIOS method, please check the following website for more information:

How to create a bootable DOS USB thumb drive:

http://www.technetsavvy.com/2011/08/how-to-format-and-create-ms-dos-98.html

BIOS Update:

http://www.technetsavvy.com/2011/08/how-to-revert-to-older-version-of-bios.html

image

After the BIOS update to 1103, the problem will be solved.

Reference:
http://vip.asus.com/forum/view.aspx?id=20091209230843390&board_id=20&model=Eee+PC+1008HA&page=1&SLanguage=en-us Print Friendly and PDF
Share/Bookmark

Critical Java zero-day attack is being protected Symantec Endpoint Protection (SEP) 12.1.2

A new zero-day exploit in Java has been found in the wild. Currently, this exploit is being used by toolkits like the Blackhole Exploit Kit (BHEK) and the Cool Exploit Kit (CEK).

The SEP 12.1.2 Virus and Spyware Protection Def. is 11-01-2013 r37, Proactive Threat Protection Def. is 07-01-2013 r11 and Network Threat Protection Def. is 11-01-2013 r12.

AV_Def

I go to the website which is able to test this vulunerability:

image

image

The Java attack contect is being blocked by SEP.

image

image

For more information:

http://avpclub.alone.tw/discuz/viewthread.php?tid=44016

http://www.ithome.com.tw/itadm/article.php?c=78317

http://www.avpclub.ddns.info/discuz/viewthread.php?tid=45430

http://blog.trendmicro.com/trendlabs-security-intelligence/java-zero-day-exploit-in-the-wild-spreading-ransomware/

Print Friendly and PDF
Share/Bookmark

Wednesday, January 9, 2013

Cisco Pre-shared Key Recovery

Run the following command will decrypt those pre-shared key in the configuration file:

 

more system:running config

 

Reference:

https://mebsd.com/cisco/cisco-show-run-vs-show-run-all-vs-more-systemrunning-config.html

http://www.cisco.com/en/US/products/hw/vpndevc/ps2030/products_tech_note09186a00807f2d37.shtml

Print Friendly and PDF
Share/Bookmark

Tuesday, January 8, 2013

Windows Server 2008 R2 Rebuild Mirror (Windows build-in software RAID 1)

<You must backup all the data before to rebuild mirror>

There are mirror volume (RAID 1) have been created by two physical disk (Disk 1 and Disk 2)

The Disk 2 volume is become missing and it is become “Foreign Disk” like the following:

1

The solution is the following:

1. Full backup the disk 1 (The disk and volume is still healthy).

2. Select Disk 1, right click, “Remove Mirror ….”

2

3. Select the “Missing” disk and Remove mirror.

3

4. Click “Yes”

4

5. Select the “Foreign Disk” and right click, then “Import Foreign Disk……”

5

6. Press “OK”

6 

7. Press “OK”

7

8. You will got a new volume like the following disk 2:

8

9. Select disk 2 (which is you just import) and delete the volume.

9

10. Press “Yes” (Check the selected volume very carefully, do not select the wrong volume, otherwise all data will be deleted)

10

11. Select disk 2, right click and select “Convert to Dynamic Disk….”

11

12. Press “OK”

12

13. Select disk 1 and right click “Add Mirror….”

13

14. Click “Add Mirror”

14

15. The mirror have been start to rebuild now. (Remark: I also change the drive letter for identify only)

15

Print Friendly and PDF
Share/Bookmark

Monday, January 7, 2013

How to solve Hyper-V Server 2012 CHT sconfig error

There are workaround solution to solve the following error:

1

It is because the sconfig.vbs of the Hyper-V 2012 Server (Traditional Chinese) is located at “System32\zh-TW” instead of “System32\en-US”

2

The workaround solution at the following:

1. Run the command prompt by using administrator right.

Enter “notepad”

3

2. Go to “file” –> “Open” –> “sconfig.cmd”

4 

3. Change the “en-US”  to “zh-TW” and save the file to “sconfig2.cmd”

5

4. Run “regedit”

6

5. Search the key “sconfig” and change the value of this key to “sconfig2.cmd”

7 

6. After the above change, you will able to see the sconfig auto run when you login.

8

Print Friendly and PDF
Share/Bookmark

Thursday, January 3, 2013

Nvidia GeForce GT 630 non official support RemoteFX on Hyper-V Server 2012

image

The display card is FOCUS GT630 2GB DDR3 PCI-E and the driver is GEFORCE R304 (306.97)

image

Print Friendly and PDF
Share/Bookmark

ASUS M4A87TD/USB3 (AMD 870) non-official support 32GB RAM (8GB DDR3 x 4)

image

Print Friendly and PDF
Share/Bookmark

How to check total memory of the physical host in a Hyper-V Server 2012?

In PowerShell, run “Get-WmiObject –Class Win32_ComputerSystem”

image

Print Friendly and PDF
Share/Bookmark